Doc1268169182

Adv. Date :21/12/2022

Tenderers are invited for the following tender:

TENDER
Doc1268169182 : RFI: RE-PRE-QUALIFICATION OF CONTRACTORS FOR MAIN CONTRACT WORKS FOR PROPOSED ERECTION OF A SINGLE USER DATA CENTRE WITH ANCILLARY FACILITIES AND TELECOMMUNICATION USAGE ON LOT 1180V MK 07 AT 7A TUAS AVENUE 3

ELIGIBILITY
All BCA Registered Contractors:
Applicants must comply with the following minimum requirements to participate in this tender exercise: -

1. BCA Registry of Construction under License Builder (General Builder (GB1)) Class 1
2. BCA Registry of Construction under Workhead - CW01 General Building (Grade A1)
Do note that applicants shall submit your proposed domestic sub-contractors whom shall be registered with the BCA Registry of Construction under Workheads, where applicable: -
- CR08 Piling works (Grade L6)
- SB(PT) Specialist Builder (In-situ Post-Tensioning Work)
- CR10 Pre-cast Concrete Work (Grade L5 and above)
- CR12 Ground Support & Stabilisation Works (Grade L5 and above)
- SB(SS) Specialist Builder (Structural Steelwork) (Grade S2 and above)
- ME01 Air-Conditioning, Refrigeration & Ventilation Works (Grade L6)
- ME02 Building Automation, Industrial & Process Control System (Grade L6)
- ME04 Communication & Security Systems (Grade L6)
- ME05 Electrical Engineering (Grade L6)
- ME06 Fire Prevention & Protection Systems (Grade L6)
- ME08 Internal Wiring for Telecommunications (Grade L4 and above)
- ME09 Lift & Escalator Installation (Grade L6)
- ME10 Line Plant Cabling/ Wiring for Telecommunications (Grade L4 and above)
- ME12 Plumbing & Sanitary Works (Grade L6)

Your proposed domestic M&E sub-contractors shall have at least minimum one (1) or more Data Centre Projects (Multi Storey more than 3 storey) in Singapore or oversea with minimum IT Load of 20MW and multi-storey Data Halls and green field projects. The Employer reserves the right to reject your proposed domestic M&E sub-contractors who do not meet these criteria. 

All Government Supplier Registration (GSR) Registered Contractors (formerly known as EPPU Registration):
1. BizSAFE STAR

2. Capability to BIM manual in line with BS EN ISO 19650-1:2018 and BS EN ISO 19650-2:2018 standards or compatible software

3. ISO certification (i.e. 9001, 14001, 45001, etc)

4. Financial considerations - Applicants should preferably:
• be profitable for 3 out of last 5 audited financial years
• show a positive Operating cashflow for 3 out of last
5 audited financial years
• demonstrate the following ratios (in the latest audited financials):
o Working capital ratio [Net current assets/Total assets] > 0
o Current ratio [Current assets/Current Liabilities] > 0.95
o Quick ratio [(Current Assets-Inventories)/Current Liabilities]>0.75
o Return on Total Assets [Earnings Before Interest and Tax / Total Assets]> 4%
o Return on equity [Net profit/Equity] >9%
o Debt to Assets ratio [Total liabilities/ Total Assets ] <1.2
o Debt to Equity ratio [Total Liabilities / Total Equity]< 0.83
o Sales to Working capital ratio [Revenue / Net current assets] >1
o Creditors to Sales Ratio [Trade payables / Sales Revenue] <0.3
or be able provide tenable reasons where these considerations are not fulfilled. 

5. Track records/experiences of Main Contractor/ Domestic Sub-Contractors working on data centre facilities (minimum one (1) or more Data Centre / critical infrastructure project (Multi Storey more than 3 storey) in Singapore or oversea with minimum IT Load of 20MW and multi-storey Data Halls and green field projects

6. Have a team (full time):-
- Project Director (with minimum experience of ten (10) years, handled more than $500 Million project)
- Project Manager (with minimum experience of ten (10) years, handled more than $200Million project, equipped with Construction Safety Course for Project Manager (CSCPM)
- Senior Quantity Surveyor (with minimum experience of ten (10) years, handled more than $50 Million project)
- C&S Manager (with minimum experience of ten 10 years, handled more than $100Million project)
- Electrical Manager (with minimum experience of ten (10) years with green and sustainability experience 5 years, handled more than $100 Million project)
- Mechanical Manager (with minimum experience of ten (10) years) with green and sustainability experience 5 years, handled more than $100 Million project)*
- Construction Manager (with minimum experience of thirteen (13) years, co-ordinating NSC/Consultant* handled more than $100Million project)*
- BIM Manager (with minimum experience of eight (8) years)
- QA/QC Manager (with minimum experience of five (5) years)
- Safety Manager (with minimum experience of ten (10) years)#
- Fire Safety Manager (with minimum experience of ten (10) years)#

Denotes:-
* Proposed personnel shall have at least minimum one (1) Data Centre Project (Multi Storey more than 3 storey) with minimum IT Load of 20MW (Green Field DC)
# Registered under MOM

7. Not under Business Under Surveillance (BUS) Programme from MOM

8. Not barred from participating in government and Singtel tenders

ADDITIONAL INFORMATION
1) Interested tenderer shall email to Mohamed Yusoff mohamed.yusoff@singtel.com , Tan Min Fen minfen.tan@singtel.com and Liu Na Na nana.liu@singtel.com for the invite

2) Cut-off date for request for invite must reach Mohamed Yusoff mohamed.yusoff@singtel.com, Tan Min Fen minfen.tan@singtel.com and Liu Na Na nana.liu@singtel.com by 27 Dec 2022, 12 noon sharp.

RFI CLOSING DATE / TIME
04 Jan 2023, 12.00 noon (S’pore Time)

NOTE:
For technical enquiries, please contact Tan Min Fen, Liu Na Na and Boh Khee Boon (Singtel) at email: minfen.tan@singtel.com, nana.liu@singtel.com and kheeboon.boh@singtel.com

TENDER CLOSING DATE / TIME
04/01/2023 12:00 PM (Singapore Time)

NOTES:
Interested vendors with the required eligibility shall email following for the Tender invite:
Mohamed Yusoff (Singtel) at email yusoff.syedmahudom@singtel.com

For technical enquiries, please contact following:
Min Fen Tan (Singtel) at email: minfen.tan@singtel.com
Na Na Liu (Singtel) at email: nana.liu@singtel.com

Awarded To :